Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.664
Filtrar
1.
Eur J Orthod ; 46(3)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38733349

RESUMO

OBJECTIVES: The biomechanics in achieving molar distalization may differ between fixed appliances and clear aligners in the control of tooth movement. The objective of this study was to compare the treatment effects between clear aligners (CA) and fixed appliances (FA) in patients treated with miniscrew-assisted molar distalization. METHODS: The sample consisted of 46 subjects with mild-to-moderate crowding. A total of 22 patients treated with clear aligners (age, 25.66 ±â€…6.11 years old) and 24 patients treated with fixed appliances (age, 24.04 ±â€…4.95 years old) for miniscrew-assisted molar distalization were included in this study. The dental and skeletal changes were evaluated by the pre- and post-treatment lateral cephalograms. RESULTS: Significant changes were found with the vertical variables SN-OP angle (2.24 ±â€…3.22°, P < .05) and SN-MP angle (0.73 ±â€…1.15°, P < .05) for the FA group when compared with the CA group (SN-OP angle 0.41 ±â€…2.26° and SN-MP angle -0.21 ±â€…1.38°, P > .05). Both treatment groups achieved a 2-3 mm. molar distalization with significant intrusion of the upper molars. The CA group showed significantly less distal tipping of molars (U6^PP angle -2.29 ±â€…3.29° and L6^MP angle -2.92 ±â€…2.49°, P < .05) compared to the FA group (-5.24 ±â€…4.28° and -5.53 ±â€…5.03°, P < .05). In addition, significant retraction and lingual inclination of the upper and lower incisors were found in both groups. LIMITATIONS: The changes of tooth position were evaluated by 2D lateral cephalograms, not 3D measurements. CONCLUSIONS: Compared to fixed appliances, clear aligners seemed to have better control of vertical dimension and distal tipping of molars in patients treated with miniscrew-assisted molar distalization.


Assuntos
Parafusos Ósseos , Cefalometria , Dente Molar , Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos Fixos , Técnicas de Movimentação Dentária , Humanos , Técnicas de Movimentação Dentária/instrumentação , Técnicas de Movimentação Dentária/métodos , Masculino , Feminino , Adulto , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Adulto Jovem , Desenho de Aparelho Ortodôntico , Má Oclusão/terapia , Resultado do Tratamento , Maxila , Mandíbula , Aparelhos Ortodônticos Removíveis , Incisivo , Dimensão Vertical
2.
BMC Oral Health ; 24(1): 538, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715004

RESUMO

BACKGROUND: The introduction of auxiliaries such as composite attachment has improved the force delivery of clear aligner (CA) therapy. However, the placement of the attachment may give rise to a flash, defined as excess resin around the attachment which may affect CA force delivery. This in vitro study aims to determine the differences in the force generated by the attachment in the presence or absence of flash in CA. MATERIALS AND METHODS: Tristar Trubalance aligner sheets were used to fabricate the CAs. Thirty-four resin models were 3D printed and 17 each, were bonded with ellipsoidal or rectangular attachments on maxillary right central incisors. Fuji Prescale pressure film was used to measure the force generated by the attachment of CA. The images of colour density produced on the films were processed using a calibrated pressure mapping system utilising image processing techniques and topographical force mapping to quantify the force. The force measurement process was repeated after the flash was removed from the attachment using tungsten-carbide bur on a slow-speed handpiece. RESULTS: The intraclass correlation coefficient showed excellent reliability (ICC = 0.96, 95% CI = 0.92-0.98). The average mean force exerted by ellipsoidal attachments with flash was 8.05 ± 0.16 N, while 8.11 ± 0.18 N was without flash. As for rectangular attachments, the average mean force with flash was 8.48 ± 0.27 N, while 8.53 ± 0.13 N was without flash. Paired t-test revealed no statistically significant difference in the mean force exerted by CA in the presence or absence of flash for both ellipsoidal (p = 0.07) and rectangular attachments (p = 0.41). Rectangular attachments generated statistically significantly (p < 0.001) higher mean force than ellipsoidal attachments for flash and without flash. CONCLUSION: Although rectangular attachment generated a significantly higher force than ellipsoidal attachment, the force generated by both attachments in the presence or absence of flash is similar (p > 0.05).


Assuntos
Técnicas de Movimentação Dentária , Humanos , Técnicas In Vitro , Técnicas de Movimentação Dentária/instrumentação , Análise do Estresse Dentário , Desenho de Aparelho Ortodôntico , Resinas Compostas/química , Impressão Tridimensional
3.
Clin Oral Investig ; 28(5): 258, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637429

RESUMO

OBJECTIVES: To investigate the effects of material type and thickness on force generation and distribution by aligners. MATERIALS AND METHODS: Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films. RESULTS: The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm. CONCLUSIONS: Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. CLINICAL RELEVANCE: This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.


Assuntos
Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária , Humanos , Fenômenos Biomecânicos , Resultado do Tratamento , Técnicas de Movimentação Dentária/métodos
4.
Medicine (Baltimore) ; 103(17): e38004, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669369

RESUMO

This paper demonstrates a digital manufacturing technique of a removable orthodontic appliance from an intraoral scan. An intraoral scan was made for the maxillary and mandibular arches. 3Shape Orthodontics Appliance Designer produced the virtual Hawley retainer, consisting of alloy components (Adam Clasps and Fitted Labial bow) and a base plate. The base plate design was modified to adapt to inserting the alloy components, which were combined using cold-cured acrylic. The finished Hawley retainer was assessed intraorally. The described technique emphasizes the design specifications of digitally designed and manufactured removable orthodontic appliances. A combination of additive and subtractive techniques was successfully employed to manufacture the alloy components and base plate. This novel method provides an alternative approach to manufacturing removable appliances with computer-aided design (CAD)/computer-aided manufacturing (CAM) technologies. The described process offers a precursor to digital manufacturing of other developed designs of dental appliances.


Assuntos
Desenho Assistido por Computador , Impressão Tridimensional , Humanos , Desenho de Aparelho Ortodôntico , Polímeros , Benzofenonas , Polietilenotereftalatos , Cetonas , Ligas , Aparelhos Ortodônticos Removíveis
5.
Head Face Med ; 20(1): 27, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671525

RESUMO

BACKGROUND: The aim of the investigation was to evaluate if a Class II malocclusion in adult patients can be successfully corrected by maxillary total arch distalization with interradicular mini-screws in combination with completely customized lingual appliances (CCLA). METHODS: Two patient groups were matched for age and gender to determine differences in the quality of final treatment outcome. The treatment results of 40 adult patients with a Class I malocclusion (Group 1) were compared with those of 40 adult patients with a moderate to severe Class II malocclusion (Group 2). All patients had completed treatment with a CCLA (WIN, DW Lingual Systems, Bad Essen, Germany) without overcorrection in the individual treatment plan defined by a target set-up. To compare the treatment results of the two groups, 7 measurements using the American Board of Orthodontics Model Grading System (ABO MGS) and linear measurements for anterior-posterior (AP) and vertical dimensions were assessed at the start of lingual treatment (T1), after debonding (T2B), and compared to the individual target set-up (T2A). RESULTS: A statistically significant AP correction (mean 4.5 mm, min/max 2.1/8.6, SD 1.09) was achieved in Group 2, representing 99% of the planned amount. The planned overbite correction was fully achieved in both the Class I and Class II groups. There was a statistically significant improvement in the ABO scores in both groups (Group 1: 39.4 to 17.7, Group 2: 55.8 to 17.1), with no significant difference between the two groups at T2B. 95% of the adult patients in Group 1 and 95% in Group 2 would meet the ABO standards after maxillary total arch distalization with a CCLA and interradicular mini-screws. CONCLUSIONS: CCLAs in combination with interradicular mini-screws for maxillary total arch distalization can successfully correct moderate to severe Class II malocclusions in adult patients. The quality of the final occlusal outcome is high and the amount of the sagittal correction can be predicted by the individual target set-up.


Assuntos
Má Oclusão Classe II de Angle , Humanos , Má Oclusão Classe II de Angle/terapia , Feminino , Masculino , Adulto , Resultado do Tratamento , Parafusos Ósseos , Adulto Jovem , Técnicas de Movimentação Dentária/métodos , Técnicas de Movimentação Dentária/instrumentação , Maxila/cirurgia , Procedimentos de Ancoragem Ortodôntica/métodos , Procedimentos de Ancoragem Ortodôntica/instrumentação , Estudos Retrospectivos , Desenho de Aparelho Ortodôntico
6.
J Am Dent Assoc ; 155(5): 417-425, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38573273

RESUMO

BACKGROUND: Orthodontic treatment for patients with dentinogenesis imperfecta (DGI) can be risky because of the fragility of their dental hard tissue. Although the Invisalign (Align Technology) clear aligner system should be a suitable orthodontic appliance for patients with DGI, to the authors' knowledge, there has been no related research. CASE DESCRIPTION: A 28-year-old woman with DGI sought treatment with a 1 mm open bite, edge-to-edge occlusion of the central incisors, and a bilateral Class III cusp-to-cusp molar relationship. Invisalign was applied for her treatment, and after 3 and one-half years of orthodontic therapy, a normal overjet and overbite were achieved, accompanied by retraction of the lower lip as well as a bilateral Class I molar relationship. In addition, there was no iatrogenic injury to the patient's teeth. PRACTICAL IMPLICATIONS: The Invisalign system may be a suitable orthodontic appliance for patients with DGI because clear aligners lessen the tensile stress to the teeth, decrease the number and area of bonds to the teeth, and offer protective effects through a full wrap of plastic that covers the crowns of the teeth.


Assuntos
Dentinogênese Imperfeita , Humanos , Feminino , Adulto , Dentinogênese Imperfeita/terapia , Aparelhos Ortodônticos Removíveis , Técnicas de Movimentação Dentária/instrumentação , Técnicas de Movimentação Dentária/métodos , Ortodontia Corretiva/métodos , Ortodontia Corretiva/instrumentação , Desenho de Aparelho Ortodôntico
8.
J Vis Exp ; (204)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38465919

RESUMO

Since the introduction of Invisalign by Align Technology, Inc. in 1999, questions and debates have persisted regarding the precision of Invisalign (clear aligner) therapy, particularly when compared to the use of traditional fixed appliances. This becomes particularly significant in cases involving anteroposterior, vertical, and transverse corrections, where precise comparisons are of paramount importance. To address these inquiries, this study introduces a meticulously devised protocol, placing a primary emphasis on digitally superimposing the movement of maxillary posterior teeth to facilitate accurate analysis. The sample included 25 patients who had completed their first series of Invisalign (clear) aligners. Four maxillary digital models (pre-treatment, post-treatment, ClinCheck-initial, and final models) were digitally superimposed using the palate rugae and dentitions as stable references. A software combination was used for model superimposition and tooth segmentation. Transformation matrices then expressed the differences between the achieved and predicted tooth positions. Thresholds for clinically relevant differences were at ±0.25 mm for linear displacement and ±2° for rotation. Differences were assessed using Hotelling's T-squared tests with Bonferroni correction. The mean differences in rotation (2.036° ± 4.217°) and torque (-2.913° ± 3.263°) were significant statistically and clinically, with p-values of 0.023 and 0.0003 respectively. De-rotation of premolars and torque control for all posterior teeth were less predictable. All mean differences for the linear measurements were statistically and clinically insignificant, except that the first molars seemed slightly (0.256 mm) more intruded than their predicted position. The clear aligner system appears to meet its prediction for most translational tooth movements and mesial-distal tipping in maxillary posterior teeth for non-extraction cases with mild to moderate malocclusions.


Assuntos
Má Oclusão , Desenho de Aparelho Ortodôntico , Humanos , Má Oclusão/terapia , Dente Pré-Molar , Dente Molar , Palato
9.
Eur J Orthod ; 46(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488436

RESUMO

BACKGROUND: Environmental sustainability has been brought into the limelight due to the global climate crisis. This crisis is driven by human activities and even the healthcare sector is no exception. Within dentistry, orthodontics is a large global market; hence, the use of post-orthodontic retainers has a significant environmental footprint. The aim of this study was to determine the environmental sustainability of post-orthodontic retention using Hawley and Essix retainers. MATERIALS AND METHODS: A comparative life-cycle assessment (LCA) was carried out to compare the environmental impact of both retainers. All inputs and outputs were accounted for using the Ecoinvent database, v3.7.1, and openLCA software. Sixteen impact categories were used to determine their environmental burden. RESULTS: Of the 16 impact categories, the Hawley had a greater environmental burden than the Essix retainer in 12 categories. The Hawley's most significant contributors to its impact values are factory manufacturing and in-house production, with an average of 41.45% and 52.52%, respectively. For the Essix, the greatest contributor is factory manufacturing, with an average of 64.63%. However, when factoring in the lifespan of the retainers, the Essix would have a greater environmental impact than the Hawley retainer. LIMITATIONS: This study employed a comparative LCA. There were also assumptions made, but these were supported by research. CONCLUSIONS: On the basis of the evidence gathered in this study, Hawley retainers are more environmentally sustainable than Essix retainers. These results would better enable clinicians to factor in the environmental impact and make informed decisions on the choice of retainer type.


Assuntos
Desenho de Aparelho Ortodôntico , Contenções Ortodônticas , Humanos
10.
J Contemp Dent Pract ; 25(1): 41-51, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514430

RESUMO

AIM: The study aims to correlate the frictional forces (FF) of four different types of commercially available ceramic brackets to their surface topography. MATERIALS AND METHODS: Two monocrystalline (MC) brackets (CLEAR™, Adanta, Germany; Inspire ICE™, Ormco, USA), one polycrystalline (PC) bracket (Symetri Clear™, Ormco, USA), one clear hybrid esthetic bracket (DISCREET™, Adanta, Germany), and a stainless-steel (SS) bracket (Victory™, 3M Unitek, USA) served as control. Both static friction (SF) and kinetic friction (KF) were recorded during sliding using an Instron universal machine in dry settings. The bracket slot surface topography was evaluated. A scanning electron microscope (SEM) and a profilometer machine were used for assessment before and after sliding. RESULTS: Frictional forces values during sliding were as follows in descending order; Inspire ICE™, CLEAR™, DISCREET™, Symetri Clear™, and, lastly, Victory™. Also, DISCREET™ scored the highest in surface roughness (Sa) values followed by Symetri Clear™. None of the correlations were statistically significant. CONCLUSION: Frictional forces produced during sliding were not always directly related to surface roughness. Monocrystalline ceramic brackets appeared to have the greatest FF and a low surface roughness. Furthermore, DISCREET™ scored a very low frictional value comparable to metal brackets yet showed the highest surface roughness. Metal brackets exhibited the greatest surface smoothness before sliding and the least SF. CLINICAL SIGNIFICANCE: Predicting the FFs produced during sliding mechanics would help the practitioner while choosing the bracket system to be used, and while planning the treatment mechanics, how much force to deliver, and how much tooth movement to expect. How to cite this article: AlBadr AH, Talic NF. Correlating Frictional Forces Generated by Different Bracket Types during Sliding and Surface Topography Using Scanning Electron Microscopy and Optical Profilometer. J Contemp Dent Pract 2024;25(1):41-51.


Assuntos
Braquetes Ortodônticos , Microscopia Eletrônica de Varredura , Fricção , Fios Ortodônticos , Desenho de Aparelho Ortodôntico , Análise do Estresse Dentário , Estética Dentária , Metais , Aço Inoxidável/química , Teste de Materiais , Propriedades de Superfície
11.
Clin Oral Investig ; 28(3): 183, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38424224

RESUMO

OBJECTIVE: To analyse three protocols in maintaining the stability of orthodontic therapy results and their effect on gingival health. MATERIALS AND METHODS: Sixty-six subjects (pre-therapeutic age 11-18 years; 68% female) randomly allocated into three retention groups of equal size were analysed. The first group had a 0.673 × 0.268 mm (0.027 × 0.011 inches) rectangular braided steel retention wire bonded to the lingual surfaces of all mandibular teeth from canine to canine, and the second group had a 0.406 mm (0.016 inches) round twisted steel wire. The third group was the control, without wires, and only with vacuum-formed retainers. All three groups had vacuum-formed removable retainers in the maxilla. The frequency of wire detachment/breakage/loss of retainer, the occurrence of crowding of mandibular incisors, and changes in intercanine width and gingival health were monitored. RESULTS: Incidence and severity of relapse differed between groups (p = 0.001 and 0.049) being most common in the removable retainer group (incidence 68.2%; severity 0.7 ± 1.0 mm), followed by the round wire group (36.4%; 0.5 ± 1.2 mm) and rectangular wire group (13.6%; 0.1 ± 0.1 mm). The intercanine width decreased more without a bonded retainer (incidence 68.2%; severity 0.5 ± 0.7 mm) and with the round wire more (45.5%; 0.5 ± 0.7 mm) than with the rectangular (27.3%; 0.1 ± 0.3 mm). The difference was significant for incidence (p = 0.025), but not severity. Detaching of the wires/breakage/loss of retainer was similar. There were no significant differences in the accumulation of biofilm, calculus and gingivitis between appliances. CONCLUSION: A rectangular wire is the most effective in retention, and the impact of retention appliances on gingival health is similar. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05121220. Registered 02 October 2021 - Retrospectively registered. CLINICAL RELEVANCE: Studying guidelines for reducing relapse, proper use of materials and appliances, the behavior of retention wires according to their profile in the retention phase, and possibilities of maintaining oral health will contribute to improving the stability of orthodontic therapy results.


Assuntos
Desenho de Aparelho Ortodôntico , Contenções Ortodônticas , Adolescente , Criança , Feminino , Humanos , Masculino , Mandíbula , Aparelhos Ortodônticos Fixos , Recidiva , Aço
12.
J World Fed Orthod ; 13(2): 65-71, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38395726

RESUMO

BACKGROUND: A finite element model was used to investigate the effect of different designs and thicknesses of orthodontic aligner margins on their biomechanical behavior. METHODS: A three-dimensional data set of an upper jaw was imported into the 3-matic software. The upper right central incisor tooth (Tooth 11) was separated from the remaining model, and its periodontal ligament and surrounding bone were designed. Aligners were designed with four different trimming lines (scalloped, straight, scalloped extended, straight extended), each with four different thicknesses (0.3, 0.4, 0.5, and 0.6 mm). The models were imported into a finite element package (Marc/Mentat). A linear elastic constitutive material model was applied. A facial 0.2 mm bodily malalignment of tooth 11 was simulated. RESULTS: The maximum resultant force was in the range of 1.0 N to 2.2 N. The straight trimming designs deliver higher resultant forces compared with scalloped trimming designs. Increasing the aligner thickness and/or extending the aligner edge beyond the gingival line leads to an increase in the resultant force. All designs showed an uneven distribution of the normal contact forces over the tooth surface with a predominant concentration toward the cervical third and distal third, particularly with the extended trimming designs. All designs showed uncontrolled tipping of the tooth. CONCLUSIONS: Based on the current model outcomes, the use of a straight extended trimming line design for aligners is favored because of its positive impact on force distribution and, consequently, the control of tooth movement. CLINICAL RELEVANCE: These findings provide aligner companies and orthodontists a valuable biomechanical evidence and guidance to enhance control over tooth movement and therefore optimize treatment outcomes. This can be achieved by trimming the edges of aligners with a straight extended design and selecting the appropriate aligner thickness.


Assuntos
Fenômenos Mecânicos , Desenho de Aparelho Ortodôntico , Análise de Elementos Finitos , Software , Maxila , Técnicas de Movimentação Dentária/métodos
13.
BMC Oral Health ; 24(1): 191, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317101

RESUMO

AIM: There is limited research on the clinical performance of double-thread orthodontic miniscrews. This study aimed to compare the stability of double-thread and single-thread orthodontic miniscrews and identify the potential associations between patient-related and location-related factors with miniscrew stability. METHODS: This retrospective cohort study involved 90 orthodontic miniscrews (45 single-thread, 45 double-thread) with identical dimensions (8 mm length, 1.6 mm diameter). The screws were inserted in various locations within the upper jaw of 83 patients (54 females, 29 males; mean age = 15.1 ± 2.4 years). Failure was defined as excessive mobility or loss of miniscrew after placement. The data recorded were patient age, gender, insertion site, side of insertion (buccal or lingual), duration of force application, and failure occurrence. RESULTS: The overall success rate within the sample was 92.2%. Double-thread miniscrews exhibited a significantly higher success rate than single-thread miniscrews (P = 0.049), with 97.8% and 86.7% success rates, respectively. Gender, age, insertion location, and side of insertion did not show significant associations with failure (P > 0.05). Log-rank analysis revealed a significant difference between the two groups (P = 0.046), indicating a higher probability of survival for the double-thread design. CONCLUSIONS: The overall success rate of orthodontic miniscrews was high in the present sample. Double-thread miniscrews placed in various locations within the maxillary arch demonstrated superior stability and survival rates compared to their single-thread counterparts. Therefore, double-thread miniscrews may be preferred when bone quality is inadequate, such as in young patients.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Desenho de Aparelho Ortodôntico , Masculino , Feminino , Humanos , Criança , Adolescente , Estudos Retrospectivos , Parafusos Ósseos , Maxila/cirurgia
14.
Eur J Orthod ; 46(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38394353

RESUMO

BACKGROUND: CAD/CAM (computer-aided design/computer-aided manufacturing) fixed retainers (FRs) as an alternative to multistranded FRs to maintain orthodontic treatment outcome. OBJECTIVES: The primary aim was to compare CAD/CAM versus conventional multistranded FRs in terms of stability until 2 years. Secondary outcomes were failure rates, patient satisfaction, and cost-minimization. TRIAL DESIGN: 2-arm parallel, two-centre randomized controlled trial. METHODS: Patients were randomized to CAD/CAM or conventional FRs in both arches, in a 1:1 ratio and blocks of four. Allocation concealment was secured by using sequentially numbered envelopes. Patients were blinded. FRs were bonded at the end of treatment, and patients were recalled after 12 and 24 months. First-time retainer failures were recorded and digital impressions were taken. Arch widths and lengths, as well as Little's Irregularity Index (LII), were measured. Additionally, patients answered satisfaction questionnaires. Linear mixed models were applied for measurements and patient satisfaction. Survival analyses were estimated with Kaplan-Meier curves, along with Cox-regression modelling. Cost-minimization analysis was undertaken. RESULTS: One hundred and eighty-one patients were randomized (98 in Centre 1, and 83 in Centre 2): 90 in CAD/CAM and 91 in conventional group. One hundred and fifty three patients attended T24 follow-up. There were no significant differences in LII and arch dimensions between groups for failure-free patients. Within 24 months, 34% maxillary CAD/CAM FRs and 38% maxillary conventional FRs failed, along with 42% mandibular CAD/CAM FRs and 40% mandibular conventional FRs, with no significant difference in survival between groups (hazard ratios conventional to CAD/CAM: maxillary arch: 1.20 [P = 0.46], mandibular arch: 0.98 [P = 0.94]). There were no significant differences in patient satisfaction between groups. No harms were observed. Cost-minimization analysis showed that CAD/CAM FRs were slightly cheaper than conventional FRs. CONCLUSIONS: There were no clinically significant differences in LII, arch widths, and lengths between CAD/CAM and conventional FRs after 24 months. There were no differences in failures and patient satisfaction between groups. CAD/CAM FRs were slightly cheaper than conventional FRs. TRIAL REGISTRATION: ClinicalTrials.gov NCT04389879.


Assuntos
Contenções Ortodônticas , Satisfação do Paciente , Humanos , Seguimentos , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Fixos
15.
BMC Oral Health ; 24(1): 236, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355505

RESUMO

OBJECTIVE: Aim of this randomized clinical controlled trial was to evaluate the influence of fixed orthodontic steel retainers on gingival health and recessions of mandibular anterior teeth. MATERIALS AND METHODS: After end of the orthodontic treatment, patients were randomly assigned into the test (fixed steel retainer) or control group (modified removable vacuum-formed retainer). Periodontal parameters (periodontal probing depth: PPD; recession: REC; bleeding on probing: BOP) as well as plaque and gingival index were assessed on mandibular anterior teeth directly before attaching/handing over the retainer (baseline: BL), 6 and 12 months after orthodontic treatment. RESULTS: 37 patients (test: n = 15, mean age: 16.1±4.2 years; control: n = 17, mean age: 17.1±5.4 years) completed the study. REC and PPD failed to show significant pairwise differences. The number of patients showing gingival health in the area of the mandibular anterior teeth (test: BL n = 10, 6 months n = 9, 12 months n = 11; control: BL n = 10, 6 months n = 16, 12 months n = 15) revealed a significant difference for the intra-group comparison between BL and 6 months in the control group (p = 0.043). The inter-group comparisons failed to show significant differences. CONCLUSION: Young orthodontically treated patients with fixed steel retainers show in 73.3% healthy gingival conditions after one year which are comparable to the control group (88.2%). Gingival recessions were in a clinically non-relevant range at any time of the examination. CLINICAL TRIAL NUMBER: DRKS00016710.


Assuntos
Doenças da Gengiva , Retração Gengival , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Aço , Gengiva , Periodonto , Retração Gengival/etiologia , Desenho de Aparelho Ortodôntico
16.
BMC Oral Health ; 24(1): 221, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38347491

RESUMO

OBJECTIVE: One of the most imprortant factors in achieving ideal teeth positions is the precision of the slot dimensions of orthodontic brackets into the archwires are inserted.This study aimed to assess the accuracy of the dimensions of orthodontic bracket slots and molar buccal tube apertures and to compare them with the specifications provided by the manufacturers. METHOD: A total of sixty brackets and ten molar buccal tubes with varying slot heights were examined using a scanning electron microscope from the mesial side. The dimensions and morphology of these bracket slots and buccal tubes apertures were assessed using the AutoCAD Software. A one-sample t-test was conducted to compare the measurements with the values provided by the manufacturer. RESULTS: The findings of the present study indicated that the height of the measured bracket slots and buccal tube apertures dimensions were significantly larger than the actual dimensions and exhibiting divergent walls. On the other hand, the depth of the brackets slots showed significantly smaller values than the actual one. CONCLUSION: A need for careful consideration when selecting a commercially accessible brand for everyday use is essential as certain materials may not meet acceptable standards.


Assuntos
Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Humanos , Microscopia Eletrônica de Varredura , Fios Ortodônticos , Teste de Materiais , Aço Inoxidável , Torque , Análise do Estresse Dentário
18.
Am J Orthod Dentofacial Orthop ; 165(5): 503-512, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38231167

RESUMO

INTRODUCTION: This retrospective investigation aimed to determine whether the achieved changes in the treatment of Class II malocclusion were the same as those planned after the prescribed wear of an initial phase of Invisalign treatment with the mandibular advancement appliance (MAA) (Align Technology, Santa Jose, Calif). METHODS: All patients treated with the MAA and who satisfied inclusion/exclusion criteria were selected from a database of 16,500 patients treated with clear aligners by 16 orthodontists. The pretreatment, planned, and achieved overjet measurements were documented from data provided in Align Technology's software facility, ClinCheck. Changes in intermaxillary anteroposterior (AP) first permanent molar (FPM) relationships were evaluated using Geomagic Control X (3D systems, Rock Hill, SC) metrology software. RESULTS: Most of the 195 patients who satisfied the inclusion criteria were females (n = 104; 53.3%). The mean age was 12.62 ± 2.20 years. The pretreatment overjet was reduced from 6.49 ± 2.86 mm to 4.61 ± 2.22 mm after prescribed MAA wear, which was 42.5% of the planned outcome. The pretreatment AP FPM reduced from 3.14 ± 1.95 mm to 2.24 ± 2.51 mm, which was 31.3% of that planned. Thirty-eight (19.5%) patients experienced an increase in overjet where a reduction was planned. CONCLUSIONS: Less than half of the planned overjet reduction and less than a third of the planned AP FPM correction were achieved with the MAA. Almost 20% of patients completed the MAA phase of treatment with an increased overjet despite a reduction being planned.


Assuntos
Má Oclusão Classe II de Angle , Avanço Mandibular , Humanos , Estudos Retrospectivos , Feminino , Má Oclusão Classe II de Angle/terapia , Avanço Mandibular/instrumentação , Avanço Mandibular/métodos , Masculino , Resultado do Tratamento , Criança , Adolescente , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Removíveis
19.
Orthod Craniofac Res ; 27(3): 455-464, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38180289

RESUMO

INTRODUCTION: Maxillary expansion is a fundamental interceptive orthodontic treatment, which can be achieved through either a rapid expansion protocol or functional devices. However, no data exist about the efficacy of functional devices in achieving skeletal expansion. Therefore, the aim of this study was to compare the effects of the rapid palatal expander (RPE) and the function-generating bite type M (FGB-M) on the transversal dimension of the maxilla, and on the maxillary and mandibular dental arch width. METHODS: One hundred eighty-one skeletal Class I patients, aged between 6 and 12 years and with a cervical vertebral maturation stage II or III, with maxillary transversal deficiency were retrospectively enrolled; among these 55 were treated with FGB-M, 73 were treated with RPE and 51 were untreated subjects retrieved from historical databases. The pre-treatment (T0) and post-treatment (T1) frontal cephalograms were retrieved, and the maxillary and mandibular widths, and the distance between upper and lower first molars were measured. T1-T0 interval was of 17.3 months (RPE), 24.6 months (FGB-M) and 18.2 months (controls). RESULTS: The statistical analysis showed that there were no statistically significant differences between the RPE and FGB-M groups regarding skeletal and dental expansion, while the untreated control group differed significantly from the other two groups. CONCLUSION: The comparison between patients treated with RPE and FGB-M showed that there were no statistically significant differences between the RPE and FGB-M groups regarding the amount of skeletal expansion and dental arch width, suggesting that both appliances can be used to achieve similar results.


Assuntos
Cefalometria , Arco Dental , Maxila , Aparelhos Ortodônticos Funcionais , Técnica de Expansão Palatina , Humanos , Técnica de Expansão Palatina/instrumentação , Criança , Masculino , Feminino , Estudos Retrospectivos , Arco Dental/patologia , Mandíbula , Desenho de Aparelho Ortodôntico , Má Oclusão Classe I de Angle/terapia , Resultado do Tratamento , Vértebras Cervicais , Ortodontia Interceptora/instrumentação
20.
Orthod Craniofac Res ; 27(3): 465-473, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38205876

RESUMO

INTRODUCTION: This study aimed to compare achieved movements with predicted movements after 28-week use of Invisalign Lite aligners. SETTINGS AND SAMPLE POPULATION: The digital impressions of 21 subjects treated with Invisalign Lite at a private practice and in the dental clinic (Milan, Italy) were taken and analysed. Subjects were Caucasian with a mean age of 20.1 years. METHODS: Patients were analysed at two time points: at T0, before starting therapy, and at T1, after 28 weeks of treatment with Invisalign clear aligners, with a 2-week change interval. The changes that occurred between T0 and T1 were compared to the predicted changes between T0 and Ts (setup/ClinCheck). Tooth movement performance was estimated through variables calculated as the difference between obtained and planned movements. RESULTS: In both maxillary and mandibular arches, the teeth that exhibited the least accurate expression of torque were the central incisors. Tip was not accurate on maxillary central incisors and canines, mandibular central incisors, lateral incisors, first premolars, second premolars and first molars. Rotations were under-expressed on maxillary lateral incisors, canines and second premolars and on mandibular central incisors, canines, first premolars, second premolars and first molars. The overall angular changes showed a tendency to underperformance. Transverse linear changes were accurate with a significant overperformance on maxillary and mandibular first molars. CONCLUSIONS: Torque correction of maxillary central incisors, as well as rotational correction of most of the teeth, showed significant differences between what was planned and what was obtained.


Assuntos
Técnicas de Movimentação Dentária , Humanos , Técnicas de Movimentação Dentária/instrumentação , Feminino , Estudos Prospectivos , Masculino , Adulto Jovem , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Removíveis , Adolescente , Adulto , Incisivo , Torque , Resultado do Tratamento , Mandíbula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA